Menu

Custom Home Builder Sunshine Coast

Durisol-Nexcem ICF insulated concrete forms for the Sunshine Coast and Brisbane

Choosing superior, environmentally friendly materials like Durisol-Nexcem ICF insulated concrete forms for your design will guarantee that your building will endure for generations, while having minimal impact on the environment around us.

Durisol-Nexcem Insulated Concrete Form ICF Comparison

When designers and builders make cost-effective and technically superior decisions in a manner that is environmentally responsible, they are providing the best design solution for both the owner and the environment

ICF Performance Benefits

  • Fireproof (4 hr Fire Rating, 0 Smoke Spread, 0 Flame Spread)
  • Moisture Resistant
  • Soundproof
  • Promotes Healthy Interiors (breathable / inhibits mold)
  • More Energy Efficient (Insulation on Exterior of Thermal Mass)
  • Impact Resistant
  • Termite/Vermin Resistant

 

Berens Construction is a Certified builder of Durisol-Nexcem ICF insulated wall form system for Queensland Australia

Call us for more information.

Healthy
While the Durisol-Nexcem ICF material is inert with no VOCs or off-gasing, the cement content of the Durisol-Nexcem material creates an above average pH environment at the wall surface, that inhibits the growth of fungi and mould. Furthermore, the hygroscopic nature of the material moderate’s relative humidity levels (65% RH maximum) and provides an inherent moisture regulator that keeps humidity low and further serves to repress any type of fungal growth.

Click the following on more information regarding Durisol-Nexcem ICF and Indoor Air Quality

Termite Resistant
Unlike wood and other non-hygroscopic material, Durisol-Nexcem ICF provides effective resistance to termite attack. A number of testing programs have been conducted by independent agencies such as the U.S. Forestry Service. Durisol-Nexcem samples were placed in termite infested areas for as long as six years without any destruction of the Durisol-Nexcem material.

The Durisol-Nexcem wall form was first manufactured in 1946 to help rebuild post-war Europe at time when resources were scarce. The product line has since expanded to include roof panels, floor forms, noise barriers retaining walls, bridge panels and even wine storage cabinets, With this proven history of versatility, performance and durability, your reputation can safely stand on our reputationOverview – Wall Form System

Performance Advantages
The Durisol-Nexcem Wall System has a unique combination of desirable properties. In-service advantages are outlined as follows: 

1.3.1 IMPACT RESISTANCE
Standard renders applied directly to the Durisol-Nexcem material result in a finish that is less expensive and more impact resistant than conventional EIFS systems (polystyrene, lath and render).

1.3.2 IMPROVED INDOOR AIR QUALITY
The cement content of the Durisol-Nexcem material creates an above average pH environment at the wall surface, which inhibits the growth of fungi and viruses. The Durisol-Nexcem material is completely inert with no VOCs or off-gassing. Furthermore, the hygroscopic nature of the material moderates RH level. This regulation of water vapour keeps humidity low and further serves to repress any type of fungal growth.

SOUND PROTECTION
Durisol-Nexcem wall systems provide considerable protection against unwanted noise. The sound absorptive properties of our material in combination with the mass of the wall system can provide an ideal combination of sound absorption and sound transmission properties. STC ratings for Durisol-Nexcem wall systems can range between 54 and 72, while the exposed surface of the Durisol-Nexcem Wall Form can provide Noise Reduction Coefficient (NRC) ratings as high as 1.0.

THERMAL MASS EFFECT
Materials like concrete, brick, and Durisol-Nexcem have a high heat capacity; that is, they can store a significant amount of heat energy. This benefit of thermal mass, as the ability to store heat results in reduced heating costs as the energy/heat in the wall is transferred back into the cooler air. Similarly, when the surrounding air is warmer than the walls, heat will be transferred to the thermal mass and reduce cooling energy consumption. The benefits of thermal mass are increased through the use of Durisol-Nexcem Wall Forms with insulated inserts since the majority of the insulation is located on the exterior face of the wall system. This is unlike foam concrete forms that have 50% of the insulation on the interior face and reduce the net benefit that is obtained through the effects of thermal mass.

The true benefit that is realized from thermal mass effects depends on a number of site-specific parameters such as climatic conditions and building orientation. Simple blanket statements such as “R-6.9 when including thermal mass” are inaccurate and misleading. Durisol Australia has a staff of engineers experienced in the field of Building Science who will provide customers with detailed evaluation of thermal mass effects upon request. Alternately, publications such as ASHRAE Fundamentals or ASHRAE Standard 90.1 will provide guidance to evaluation of different wall systems and corresponding dynamic effects.

NEGLIGIBLE THERMAL BRIDGING

Durisol-Nexcem wall systems are not simple one-dimensional assemblies. Real buildings are three-dimensional, with corners, window openings, etc. However, most wall R-value calculation methods, and almost all marketing brochures, do not factor in the effects of framing at windows, doors, corners, etc. Thus they tend to over-estimate the true thermal performance.

The construction details that increase energy flow through a framed wall system have little or no influence on the energy flow through the Durisol Insulated Wall Form System. Durisol Wall Forms are designed to ensure that the R-value through the core of the wall is almost the same as that through the web. This not only avoids thermal short-circuiting, it ensures uniform wall temperatures with no cold spots to encourage condensation, create discomfort, or cause dust marking.

Recent studies by Oakridge National Labs, ASHRAE 90.1 committee and other independent research agencies have shown how these factors influence the overall performance of wall systems.

FIRE RESISTANCE
The fire resistant properties of Durisol-Nexcem itself and the Durisol-Nexcem wall system as a whole provide considerable protection from fires. Tests in Canada have been conducted for two and four-hour fire ratings while in Austria, six-hour fire ratings have been obtained.

In Australia Durisol Australia obtained the non-combustibility test AS/NZ1530.1

The surface burning characteristics of Durisol-Nexcem far surpass all other types of stay-in-place formwork. Durisol-Nexcem has a flame spread and smoke spread rating of zero. Unlike foam, Durisol-Nexcem will not ignite, melt, sustain fire or release toxic fumes in the event of a fire.

  • Over 4 hour Fire Resistance Rating
  • Zero Flame Spread
  • Zero Smoke Developed
  • Zero Fuel Contributed

 

MOISTURE PROTECTION
Since no exterior finish will act as a perfect rain barrier, it is good practice to have a wall system that is capable of compensating for imperfections in the veneer. In the event that moisture does become temporarily trapped within the wall, the Durisol-Nexcem wall system is capable of accommodating this moisture without any damage to itself. Damage to other wall components is of course a possibility. Although the Durisol-Nexcem material will not prevent moisture damage, it will mitigate the effects of moisture penetration through the exterior weather barrier. The behaviour of Durisol-Nexcem in this regard is similar to any other type of cement based product with moisture storage capability – such as concrete masonry. The permeable nature of the Durisol-Nexcem material serves to regulate the water vapour in the air and provides a smoothing effect to rapid swings in relative humidity

TERMITE RESISTANCE
 Durisol-Nexcem provides effective resistance to termite attack. A number of testing programs have been conducted where Durisol-Nexcem samples were placed in termite infested areas for as long as six years without any destruction of Durisol-Nexcem material occurring.